No items
Operating conditions
Pressure: ≤ 400 bar
Temperature: -40°C...+100°C
Speed: ≤ 0,5 m/s
Fluids: Hydraulic fluids (mineral oil based)
Gap >e< defined according to operating conditions by using nomogram.
Materials
Polyurethane (harness 94 Shore A)
Installation
Closed housing (A)
Two-piece piston (B)
Advantages
- High wear resistance
- Can be used as piston and rod seal
- Inexpensive
Corresponding types: TTU, RSS
Attention! Type UI only for rod, Type UA only for piston.