Operating conditions
Pressure: ≤ 400 bar
Temperature: -35C...+110C
Speed: ≤ 0,5 m/s
Fluids: Hydraulic fluids (mineral oil based)
Gap >e< defined according to operating conditions by using nomogram.
Materials
Polyurethane (hardness 93 Shore A)
Installation
Closed housing (A) Table 1
Duplex housing (B)
Advantages
- Good wear resistance
- Economical price
Corresponding types:
RS, PDI
TTI/L, RS/L (dual lip)
TTI/L-AI, TS/LA (dual lip, POM backup ring)