Operating conditions
Pressure: ≤ 250 bar
Temperature: -30°C...+100°C
Speed: ≤ 0,5 m/s
Fluids: Hydraulic fluids (mineral oil based), water emulsions
Gap >e< defined according to operating conditions by using nomogram.
Materials
NBR-rubber, partially fabric reinforced
Installation
Into closed housing
Tolerances
d = H8/f7
D = H9
L = +0,25 -0
Advantages
- Excellent sealing performance at low pressures due to the rubber lip
- Small risk of gap damage due to fabric reinforced part