C1 Rod seal

Operating conditions

Hydraulic                                      

Pressure:    ≤160 bar                                              

Temperature: -35°C..+100°C                                       

Speed:         ≤0,5 m/s                                                  

Fluids:         Mineral oil based hydraulic fluids                                        

Pneumatic

Pressure:  ≤16 bar

Temperature: -35°C..+80°C

Speed: 1 m/s

Fluids: Oil lubricated pressurized air

Profile E5 recommended for permanent lubricated pneumatic systems


Gap >e< defined according to operating conditions by using nomogram.

Materials

NBR based elastomer

Installation

Into closed housing

Nominal dimension < 25 mm, open housing recommended

Tolerances

d = H11/e9  Pneumatic

d = H8/f7     Hydraulic

D = H9

L = +0,20 (-0)

Advantages

- Little space required

- Low friction due to seal construction

- Can be used in pneumatics if pressurized air contains lubrication